Radiator for Perkins Diesel Engine

Radiator cooling is the most common method of cooling gen set engines. Simple and practical, they fit most applications’ needs. All gen sets can be equipped with various sizes of radiators mounted on the front of the unit. However, remote radiators can be used when adequate airflow through the gen set enclosure is not possible.
Availability:
Quantity:

Water Cooling Radiator for Generator Set

Radiator

Radiator cooling is the most common method of cooling gen set engines. Simple and practical, they fit most applications’ needs. All  gen sets can be equipped with various sizes of radiators mounted on the front of the unit. However, remote radiators can be used when adequate airflow through the gen set enclosure is not possible.

Most radiators are made up of tubes surrounded by fins (the core) that extract heat from water pumped through the system from the engine. Designed for 120 F ambient temperatures, they work best when correctly matched to engine power, ambient temperature and adequate airflow



Radiator for Perkins engine (Models are not included all)

402D-05 10.2KW

854E-E34TA 83KW

1204E-E44TA/TTA 74.5KW

403D-07 15.3KW

854E-E34TA 86KW

1204E-E44TA/TTA 82KW

403D-11 21KW

854F-E34T 55.4KW

1204E-E44TA/TTA 92.5KW

403D-15 25.1KW

854F-E34T 55.4KW

1204E-E44TA/TTA 102.1KW

403D-15T 30KW

1103C-33 43KW

1204E-E44TA/TTA 110.1KW

403D-17 24.7KW

1103C-33T 55KW

1204E-E44TA/TTA 117KW

403D-17 26KW

1103D-33 39.6KW

1204E-E44TA/TTA 129.4KW

403F-15T 24.4KW

1103D-33TA 58KW

1204F-E44TA/TTA 70KW

403F-15T 25.2KW

1104C-44 64KW

1204F-E44TA/TTA 74.4KW

403F-15T 27KW

1104C-44T 74.5KW

1204F-E44TA/TTA 82KW

404D-15 26.5KW

1104D-44TA 83KW

1204F-E44TA/TTA 85.9KW

404D-22 38KW

1104D-R44T 74.5KW

1204F-E44TA/TTA 91KW

404D-22T 45.5KW

1106C-70TA 162KW

1204F-E44TA/TTA 92.6KW

404F-22 31.4KW

1106C-70TA 145KW

1204F-E44TA/TTA 97KW

404F-22 34.1KW

1106C-70TA 137KW

1204F-E44TA/TTA 102.1KW

404F-22 35.4KW

1106C-70TA 129KW

1204F-E44TA/TTA 106KW

404F-22 35.7KW

1106C-70TA 115KW

1204F-E44TA/TTA 110.1KW

404F-22 36.4KW

1106C-70TA 105KW

1204F-E44TA/TTA 105KW

404F-22 36.4KW

1106D-E70TA 116.5KW

1204F-E44TA/TTA 112KW

404F-22T 36.4KW

1106D-E70TA 129KW

1204F-E44TA/TTA 117KW

404F-22T 36.4KW

1106D-E70TA 129KW

1204F-E44TA/TTA 129.4KW

404F-22T 40KW

1106D-E70TA 151KW

1206E-E66TA 89KW

404F-22T 41.5KW

1106D-E70TA 159KW

1206E-E66TA 116.5KW

404F-22T 44.7KW

1106D-E70TA 168KW

1206E-E66TA 129.4KW


1106D-E70TA 186KW

1206F-E70TA/TTA 116KW


1106D-E70TA 205KW

1206F-E70TA/TTA 129KW



Radiators should be sized about 10 percent greater than the engine’s heat rejection.

Radiator-2

Altitude, air temperature and velocity greatly affect cooling ability and performance. Following are some rules of thumb that may be used in general gen set cooling system sizing exercises:

  • For every 304.0m (1,000 feet) above sea level, deduct 1.38C (2 F) from the observed ambient temperature for a better indication of the air’s cooling ability.

  • In enclosed areas with an engine mounted radiator, expect ambient temperature to increase as the air passes over the generator, engine and through the radiator. Table 1 lists the estimated air to core temperatures rises in different types of installations.

  • Cooling ability drops 1 C (1.8F) for every 10 percent increase in glycol, up to 50 percent concentration.

  • Noise transmits for air inlet and outlets, so position them away from noise sensitive areas.

  • Watch prevailing winds that could cause exhaust fumes and heat or warmed outlet air to recirculate to the inlet as shown in Figures 3A and B.

  • Position radiators away from prevailing winds so winds do not act against the fan, or install a windbreak several feet in front of the outlet.

  • Use large radius turns and turning vanes to minimize turbulence and air flow restriction on inlet bends

Engine-Mounted Water Cooling Radiator

radiator

Engine-mounted radiators offer the simplest cooling system. Factory-matched for the engine and application, designers and installers need to only worry about providing adequate ventilation.

In enclosures, radiator ducting should be larger than the radiator core, with inlet air ducts 1.5 times larger than outlet air ducts. Although louvers minimize exposure to the elements and vandalism, vent size must be increased 25 percent because they inhibit air movement, even when fully open. These should mechanically, electrically or pneumatically controlled to fully open when the engine starts. However, if units are exercised at no load, louvers should automatically adjust to maintain air temperature allowing the engine to warm to normal operating temperature.

 

Remote Water Cooling Radiator

Water Cooling Radiator

Though remote radiators allow units to be placed well within a building, the heat from engine operation must be dissipated elsewhere. However, system design grows in complexity. Additional piping and fittings add to initial cost and system maintenance. In cases of long pipe runs, oversized piping may be needed to meet flow requirements.

Several installation points are unique to remote radiators. A remote radiator should not be located more than 17.5m (57 feet) above the engine water pump. Otherwise, the excessive head pressure will likely cause the water pump seal to leak.

For installations where the radiator is mounted below the engine, an expansion tank is needed. If the expansion tank is mounted on the engine, the radiator core must withstand full pump pressure. This system usually requires a round tube radiator. If the radiator has a vertical core, reverse water flow through the radiator to eliminate any trapped air in the inlet tank. EPG Designer can help you identify the best components for your installations.



For more information about radiator, please click here.


photobank (1)

Hiersun Power is an operated power solutions provider in Guangzhou, China. We provide a total power solution for businesses requiring emergency power and continuous power in areas not currently served with electricity.

We take a detailed consultative approach to your field, to ensure our clients get the right power solution for their needs, without over-specifying equipment or under-estimating requirements. Where necessary, we conduct a site audit to ensure a safe and accessible operating environment for our clients and the machinery itself.

For more detailed, please click here.