Article List
- What’s an Industrial Engine IOPU and why should you care?Once upon a time, in the not too distant past, installing a diesel engine into a piece of equipment was a relatively straightforward exercise. One simply needed to find a location with an adequate air supply for the radiator, plumb the exhaust, connect the fuel lines, and connect the transmission orTechnical news April 05, 2019
- HIERSUNPK Diesel engine 404D22T Emission European Stage 3AAPPROVAL OF AN ENGINE TYPE OR FAMILY OF ENGINE TYPES WITH REGARD TO THE EMISSION OF POLLUTANTS PURSUANT TO DIRECTIVE 97/68/EC, AS LAST AMENDED BY DIRECTIVE 2004/26/ECTechnical news January 10, 2019
- HIERSUNPK Engine number Identification GuideHIERSUNPK Engine Identification GuideIn many cases it is necessary to identify the HIERSUNPK® Engine Number in order to ascertain the correct engine kit for an application. All HIERSUNPK® Engines should contain one of the two following formats for engine numbering (dependent on the year of manufacture):PrTechnical news August 03, 2018
- Diesel Generator Lead Acid Batteries General Precautions SECTION 9 – FAULT FINDINGSECTION 9 – FAULT FINDING9 Fault FindingThe following table shows some typical faults, their possible causes and remedies.Table 9-1 Fault FindingProducts News May 21, 2018
- Diesel Generator Lead Acid Batteries General Precautions SECTION 8 – ELECTROLYTE LEVELSSECTION 8 – ELECTROLYTE LEVELS8 Electrolyte Levels and Bench Charging RatesThe following table shows the electrolyte level to be expected at a range of bench charging rates:Table 8-1 Electrolyte LevelsProducts News May 21, 2018
- Diesel Generator Lead Acid Batteries General Precautions SECTION 7 – BATTERY REPLACEMENTSECTION 7 – BATTERY REPLACEMENT1 Battery Replacement Always replace the starting battery with the same number and type (e.g. vented, lead acid). Properly dispose of battery in accordance with local environmental agency requirements.Products News May 20, 2018
- Diesel Generator Lead Acid Batteries General Precautions SECTION 6 – ELECTROLYTE - SG & TEMPERATURESECTION 6 – ELECTROLYTE - SG & TEMPERATURE6 Electrolyte - Specific Gravity and TemperatureNote: Maintenance-free batteries are sealed and do not require the addition of electrolyte. Some manufacturers of maintenance-free batteries provide an ‘eye’ or some visible means of telling when the battery isProducts News May 20, 2018
- Diesel Generator Lead Acid Batteries General Precautions SECTION 5 - MAINTENANCE PART 2SECTION 5 - MAINTENANCEProducts News May 19, 2018
- Diesel Generator Lead Acid Batteries General Precautions SECTION 5 - MAINTENANCE PART 1SECTION 5 - MAINTENANCE5 MaintenanceNote: Maintenance-free batteries are sealed and do not require the addition of electrolyte. Some manufacturers of maintenance-free batteries provide an ‘eye’ or some visible means of telling when the battery is discharged or approaching the end of its useful life.Products News May 19, 2018
- Diesel Generator Lead Acid Batteries General Precautions SECTION 4 - COMMISSIONINGSECTION 4 - COMMISSIONING4 CommissioningNote: Commissioning is to be undertaken by suitably trained and qualified service personnelonly.Lead-acid batteries supplied in dry-charged form are commissioned as follows:4.1 Pre-Commissioning Procedure1. Check for any mechanical damage to the battery case oProducts News May 18, 2018